Automatic Softening Control Valves
Structure & Performance Features
Hermetic head faces structure.
No hard water bypass and can operate with pressure.
Start regeneration by manual, and handle can be rotated 360cycle.
F64BC,F64AC could be side-operated.
- Overview
- product parameters
- product application
- Recommended Products

Working Principle
Using hermetic head faces theory, Runxin valve is designed to integrate multi-ports round closely to one
valve body. When the rotor rotates, some ports will be shut off and meanwhile some other ports wil be
open, and thus the water willflow in and out this valve.
Construction
Runxinvaeuseshigflatnessmovingdskandfixeddisktoworkasavalefxeddiskisfixedandmovngdiskisdrvenby
handeomotortorotatlosoerfixdiskerarseveralblindviatougolsonfixddiskanmvnisk
whenmovingdiskstaysondiferentpositionsoffixeddiskandthendiferentflowpassageswillbeformed:
For softener valves
These positions are Service,Backwash,Brine&Slow Rinse,Brine Refll and Fast Rinse.
For Filter valve
It has 3 positions: Service,Backwash and Fast Rinse.
Structure & Performance Features
LED display, long time power off indication and data will be saved for three days after power off.
No hard water bypass in regeneration cycle (except F92 and F130).
With signal output connector, remote handling connector which can receive passive signal.
With interlock connector which can realize service simultaneously and regeneration one by one.
N77, F95, F111 and F99 adopt ball valve for brine drawing and refil.
Time clock regeneration option: by days or by hours; Meter valve regeneration option: Meter Delayed (A-01),
Meter Immediate (A-02), Intelligent Meter Delayed (A-03), intelligent Meter Immediate (A-04).
Up-flow control valve can set interval backwash times F-0o, which can realize several times service and one time backwash.
N77, F95 and F111 have two valve cores, one is for controlling inlet water and brine drawing, another is for outlet water.
N77 and F95 with RS-485 port are optional.
Applications
Residential Softener Systems (F63/F65/F68/F69).
Softener for RO pretreatment System.
Boiler Softening System, lon exchange system.
product parameters
PRO

product parameters1
| Model | 63502(F65B1) 63602(F65B3) |
63502B (F65G1) 63602B(F65G3) |
73502(F69A1) 73602(F69A3 |
| Water Capacity | 2m³/h | 2m³/h | 2m³/h |
| Running Model | Time Clock (B1) / Meter (B3) | Time Clock(G1) / Meter (G3) | Time Clock (A1) / Meter (A3) |
| Regeneration Type | Downflow | Downflow | Upflow |
| Mount Type | Top Mount | Top Mount | Top Mount |
| Inlet/Outlet | 3/4*F | 3/4*F | 3/4"F |
| Drain | 1/2"M | 1/2"M | 1/2°M |
| Brine Tank Connector | 3/8"M | 3/8"M | 3/8"M |
| Base | 2.5°-8NPSM | 2.5°-8NPSM | 2.5"-8NPSM |
| Riser Pipe | 1.05" OD | 1,05" OD | 1.05" OD |
| Available Tank Size | 6月10日 | 6月10日 | 6"-10" |
| Working Pressure | 0.15-0.6 MPa | 0.15-0.6 MPa | 0.15-0.6 MPa |
| Water Temperature | 5-45 °℃ | 5-45°℃ | 5-45.°℃ |
| Turbidity | <5FTU | <5FTU | <2FTU |
| Input Charge | AC 100V-240V/50-60Hz | AC 100V-240V/50-60Hz | AC 100V-240V/50-60Hz |
| Output Charge | DC 12V/1.5A | DC 12V/1.5A | DC 12V/1.5A |
product parameters2
| Model | 63504B (F63G1) 63604B (F63G3) |
63604C(F6313) 63504C(F6311) |
63504S(F63B1) 63604S(F63B3) |
| Water Capacity | 4m³/h | 4m³/h | 4m³/h |
| Running Model | Time Clock (G1)/ Meter (G3) | Time Clock (I1)/Meter (3) | Time Clock (B1y Meter (B3) |
| Regeneration Type | Downflow | Downflow | Downflow |
| Mount Type | Top Mount | Side Mount | Top Mount |
| Inlet/Outlet | 1°M | 1°M | 1"M |
| Drain | 1/2"M | 1/2"M | 1/2"M |
| Brine Tank Connector | 3/B"M | 3/8"M | 3/8"M |
| Base | 2.5°-8NPSM | 2.5'-8NPSM | 2.5"-8NPSM |
| Riser Pipe | 1.05" OD | 1.05* OD | 1.05" OD |
| Available Tank Size | 6-14" | 6²-14² | 6-14" |
| Working Pressure | 0.15-0.6 MPa | 0.15-0.6MPa | 0.15-0.6 MPa |
| Water Temperature | 5-50°℃ | 5-50°℃ | 5-50°℃ |
| Turbidity | <5FTU | <5FTU | <5FTU |
| Input Charge | AC 100V-240V/50-60Hz | AC 100V-240V/50-60 Hz | AC 100V-240V/50-60Hz |
| Output Charge | DC 12V/1.5A | DC 12V/1.5A | DC 12V/1.5A |
product parameters3
| Model | 73502B (F69G1) 73602B (F69G3) |
63503(F117A1) 63603(F117A3) |
63504(F63C1) 63604(F63C3) |
| Water Capacity | 2m³/h | 2m³/h | 4m³/h |
| Running Model | TimeClock(G1) /Meter(G3) | TimeClock(A1)/Meter(A3) | Time Clock(C1) / Meter (C3) |
| Regeneration Type | Upflow | Downflow | Downflow |
| Mount Type | Top Mount | Top Mount | Top Mount |
| Inlet/Outlet | 3/4"F | 3/4"F | 1°M |
| Drain | 1/2"M | 3/4"M | 1/2"M |
| Brine Tank Connector | 3/8"M | 3/8"M | 3/8"M |
| Base | 2.5"-8NPSM | 2.5"-8NPSM | 2.5"-8NPSM |
| Riser Pipe | 1.05" OD | 1.05OD | 1.05OD |
| Available Tank Size | 6月10日 | 6°-10" | 6"-14" |
| Working Pressure | 0.15-0.6 MPa | 0.15-0.6 MPa | 0.15-0.6 MPa |
| Water Temperature | 5-50°C | 5-50°℃ | 5-50°℃ |
| Turbidity | <2FTU | <5FTU | <5FTU |
| Input Charge | AC 100V-240V/50-60Hz | AC 100V-240V/50-60 Hz | AC 100V-240V/50-60 Hz |
| Output Charge | DC 12V/1.5A | DC 12V/1.5A | DC 12V/1.5A |
product parameters4
| Model | 73504(F68C1) 73604(F68C3) |
73504B(F68G1) 73604B(F68G3) |
73504S(F68A1) 73604S(F68A3) |
| Water Capacity | 4m³/h | 4m³/h | 4m³/h |
| Running Model | Time Clock (C1)/ Meter (C3) | Time Clock(G1) / Meter (G3) | TimeClock(A1)/Meter(A3) |
| Regeneration Type | Upflow | Upflow | Upflow |
| Mount Type | Top Mount | Top Mount | Top Mount with handwheel |
| Inlet/Outlet | 1"M | 1°M | 1"M |
| Drain | 1/2"M | 1/2"M | 1/2"M |
| Brine Tank Connector | 3/8"M | 3/8"M | 3/8"M |
| Base | 2.5°-8NPSM | 2.5"-8NPSM | 2.5°-8NPSM |
| Riser Pipe | 1.05" OD | 1.05* OD | 1.05" OD |
| Available Tank Size | 6°-14* | 6"-14" | 6°-14" |
| Working Pressure | 0.15-0.6MPa | 0.15-0.6 MPa | 0.15-0.6 MPa |
| Water Temperature | 5-50°℃ | 5-50 °℃ | 5-50°℃ |
| Turbidity | <2FTU | <2FTU | <2FTU |
| Input Charge | AC100V-240V/50-60Hz | AC 100V-240V/50-60Hz | AC 100V-240V/50-60 Hz |
| Output Charge | DC 12V/1.5A | DC 12V/1.5A | DC 12V/1.5A |
Product Application
:
Filtering & Softening:
1,Industrial Fields
Water filtering and softening for boiler,heat exchange equipment,cooling system and RO system.
2,Agriculture
Water filtering andsoftening for crops and flowers irrigation,livestock drinking,vegetables and fruits washing.
3,Residential
Water fitering and softening for drinking, bathing,cooking,as well as for electric boilers, water heaters,underfloor heating and other installations.
4,Commercial
Pre-filtering and softening of RO system for drinking and domesticuse.It canbe usedfor swimmingpool filtering.
Process Water Treatment:
1,Desalination (Pure and Ultra Pure Water)
Power station boiler make-up water, laboratory, electroplating plant, integrated circuit manufacturing, pharmaceutical preparations,biochemstryrinkingwater,cosmeticsandotherfields
2,Iron and manganese removal filtration
Remove extra iron and manganese content in underground water for domestic and industrial production use.
3,Deaeration
Deaeration for boiler water to preventpiping,water tank,and other metal components from oxygen corrosion.
4,Defluoridation
Remove excess fluorine in underground water to protect people from fluorosis.